Product Details:
Model Name/Number | Trilogy200 |
Brand | Philips |
Usage/Application | Ambulance |
Modes of ventilation | CMV(VC) |
Patient Age Group | Pediatric |
Operation Mode | Battery Operated |
Pressure Support | 40 cm H2O |
Body Material | Aluminum |
Product Details:
Tidal Volume | Max. 2500 ml |
Model Name/Number | AII6000B |
Ventilation Modes | 5 |
Application | Hospital |
Patient Age Group | Adult |
Brand | Ambul |
TFT Display Size | 5.7 Inch |
Adjustable O2% | 100% |
Product Details:
Tidal Volume | Max. 2500ml |
Model Name/Number | T7 |
Brand | Ambul |
Weight | 3.5 Kg |
No of Modes | 10 Modes |
Battery Type | Li-ion rechargeable battery with 8 hours working time |
Waveform Display | 7 |
Adjustable O2 Concentration | Max. 100% |
Product Details:
Tidal Volume | 1500ml |
Ventilation Modes | 3 |
Application | Ambulance |
Modes of ventilation | CMV(VC) |
Patient Age Group | Pediatric |
Operation Mode | Battery Operated |
O2 Air Mix Option | 60% |
Li-ion Rechargeable Battery | More than 10 hours of working time |
Product Details:
Brand | Universe Surgical |
Modes of ventilation | CMV(VC) |
Patient Age Group | Adult |
Operation Mode | Battery Operated |
Number of Wheels | 4 Wheels |
Capacity | 2.2 L |
Display Size | 7 Inch |
Built-in Battery Backup Time | 12 Hours |
Medical Ventilators with built-in compressor, battery for 12 hours, O2 mixer and a nebulizer.
Main characteristics of the ventilator Flight 60:
Product Details:
Brand | Universe |
Type | Digital |
Application | Portable, ICU, Ambulance |
Patient Age Group | Pediatric |
Operation Mode | Battery Operated, Electricity Operated |
Sigh Volume | 150% of tidal volume |
Air Flow Adjustment | 1~12 times /m |
Breathing Mode | IPPV, SIPPV, IMV, SIMV, PEEP, Manu, Sigh and so on; |
Tidal Volume Adjustment | 0~1500ml |
Ventilation Capacity per Minute | ≥18L |
Oxygen Concentration | 21%~100% |
Ventilator Conformance | ≤30mL/kpa |
Respiratory Rate | 1~100/m |
I/E Ratio: | I:E: 4:1, 3:1, 2:1, 1:1, 1:1.5, 1:2.0, 1:2.5, 1:3, 1:4; |
Maximum Safe Pressure | ≤6.0kPa |
(Ptr) Range | -0.8~0.9kPa |
Transfer Time from Controlled to Assistant Respiration | 6s |
Air Flow Adjustment | 1~12 times /m |
PEEP | 0.1~1.0kPa |
Sigh Volume: | 150% of tidal volume |
Oxygen Consumption:≤1.5mPa change in pressure after 1-hour operation of oxygen cylinder of 12250kPa/40L. | |
Option: | Air compressor |
Product Details:
Model Name/Number | C1 |
Brand | Hamilton |
Usage/Application | Ambulance |
Modes of ventilation | CMV(VC) |
Patient Age Group | Pediatric |
Operation Mode | Battery Operated |
Height | 5 Feet |
Number of Wheels | 4 Wheels |
Product Details:
Model Name/Number | C2 |
Brand | Hamilton |
Patient Age Group | Adult |
Input voltage | 230V |
Power consumption | 150 W |
Oxygen supply | 600 kPa (87 psi), V'max 120 l/min |
Degree of protection | IP21 |
Display Type | Digital LCD |
4.2/5
Reviewed by 165 Users
Most Relevant Reviews