- Home
- ยป
- Our Products
- »
- Neonatal Line
Neonatal Line
Hybrid Neonatal Intensive Care Unit
Brand | Universe |
Application | Hospital |
Number of Wheels | 4 Wheels |
Height | 8 Feet |
Voltage | 220 V |
Display Type | LCD |
Frequency | 50 Hz |
Country of Origin | Made in India |
Neonatal Resuscitation Device Babypuff 1020
Material | ABS Plastic |
Frequency | 50 Hz |
Brand | Fanem |
Usage | Hospital |
Display Type | Analog |
Packaging Type | Box |
Country of Origin | Made in India |
- Light case with easy transport handle;
- PIP and PEEP regulation valve and safety valve
- Possibility of using Blender, O2 and Y with external gas source
- Support for fitting in infant warmers, walls and blender
Neonatal Resuscitation Unit
Application | Hospital |
Weight | 150 kg |
Brand | Universe Surgical |
Oxygen Flow Control | 15 litre/minute |
Oxygen Supply | 4.5 kg/cm2 Pipeline oxygen supply with quick release coupling |
Wattage | 50 W |
Breathing Rate Control | Manual |
Height | 7 Feet |
Maximum Suction | 400 mm of Hg |
Skin Temperature Accuracy | +1-0.2 Degree C within range 0.1t |
Maximum Airway Pressure | 40 cm |
Suction Control | water column |
Vacuum Gauge Range | 760 mm of Hg |
Neonatal resuscitation units are commonly used as open care incubator in the delivery room, intensive care units, operating theatres. They must combine heat control, Resuscitation, Photo therapy unit space for monitoring system and complete accessibility to the infant with an optimum medical procedure capability. Our units are fitted with advanced microprocessor that allows three setting: pre warm, manual or automatic. Further, the alarm fitted in these units indicates the power failure, temperature deviation and temperature failure. The heated head of these units can be adjusted more than 90º horizontally and the infant bed can be adjusted as per the requirement.
Features:
- Microprocessor based servo controlled temperature system
- APGAR timer to record therapy time
- Convenient X-ray cassette under infant bed
Apgar Timer:
- The digital apgar timer is switched on at the moment of birth and an acoustic alarm will sound after 1,5,10,15 and 20 minutes, reminding to examine the new born according to the apgar scheme.
Electronic Controller:
- Micro computerized system.
Skin Temperature Probe:
Range |
28°C to 38°C |
Resolution |
0.1°C |
Phototherapy Unit:
Supply to each lamp | 12 V |
Irradiance | 6 - 8 1.1.W/cm2/nm at bed lev |
Resuscitator:
Oxygen flow rate control |
0 to 6 litre/minute |
Vacuum gauge range |
0-760 mm of Hg |
Oxygen flow control |
1-15 litre/minute |
Oxygen Supply |
3.1 to 4.5 kg/cm2 Pipeline oxygen supply with quick release coupling |
Neonatal Incubator
Application | Hospital |
Brand | Universe |
Material | SS |
Frequency | 50 Hz |
Number of Wheels | 4 Wheels |
Voltage | 230 V |
Power Source | Electric |
Country of Origin | Made in India |